Destination Reporting

Where this level of security is insufficient, destination reporting can be implemented

  • This involves providing a set of isolated inputs to the elevator control system which receive feedback on which floor buttons are pressed
  • When a user badges their card, none of the relays are energized
  • When a floor is selected, the system sees the button press and in response pulses the appropriate floor relay and logs an event showing which floor the user selected